4.10 Extended Tight-Binding Methods (xTB)

4.10.2 Job Control

(July 4, 2026)

xTB calculations are requested through the usual $rem section. The only mandatory keyword is METHOD = XTB; all other controls are optional. Charge and multiplicity are specified in the standard way in the $molecule section. In xTB mode, Q-Chem automatically uses valence electrons when constructing the occupation pattern, so users should simply provide the chemically correct molecular charge and multiplicity.

METHOD

METHOD
       XTB
TYPE:
       STRING
DEFAULT:
       None
OPTIONS:
       None.
RECOMMENDATION:
       Set METHOD to XTB.

BASIS

BASIS
       XTB
TYPE:
       STRING
DEFAULT:
       XTB (implied)
OPTIONS:
       None
RECOMMENDATION:
       For METHOD = XTB, BASIS = XTB is implied and may be omitted. No other basis is allowed.

XTB_FERMI_TEMP

XTB_FERMI_TEMP
       Controls the Fermi-smearing temperature used for fractional occupations in xTB calculations.
TYPE:
       INTEGER
DEFAULT:
       300
OPTIONS:
       n0 Temperature in Kelvin.
RECOMMENDATION:
       The default is usually appropriate. Setting XTB_FERMI_TEMP = 0 recovers integer occupations.

Standard SCF controls such as SCF_ALGORITHM and SCF_CONVERGENCE are also available. SCF_ALGORITHM = DIIS is the default, while SCF_ALGORITHM = GDM or SCF_ALGORITHM = ROBUST can be useful for difficult cases.